Coal Water Slurry Steam and Hot Water Boiler
Product features:
1.The clean fuel,manufactured by premium fuel,shall solve the pollution problem at the source.
2, The problems of high running cost for oil fired boiler shall be settled.
3. The product features environmental protection and energy saving.Sulfer and dust contained in the flue gas and other enviromental protection indexed shall surpass national standard.
4, Burn out rate shall be more than 98 percent,and thermal efficiency shall be up to 85 percent and more.
5, Coal water mixture shall be transported and stored in liquid state.It shall b ingnited automaticlly,with being automatic controlled easily.So it is the perfect substitube for oil fired boiler on environmental protection and enery-saving.
Items/Model |
SZS2-1.25-J |
SZS4-1.25-J |
SZS6-1.25-J |
SZS10-1.25-J |
Rated output t/h |
2 |
4 |
6 |
10 |
Rated presure Mpa |
1.25 |
1.25 |
1.25 |
1.25 |
Steam temp. Deg C |
Saturated |
Saturated |
Saturated |
Saturated |
Feed water temp Deg C |
20 |
105 |
105 |
105 |
Combustion mode |
Chamber combustion |
Chamber combustion |
Chamber combustion |
Chamber combustion |
Applicable fuel |
Coal water mixture |
Coal water mixture |
Coal water mixture |
Coal water mixture |
Max weight of transportation part T |
31.5 |
35.5 |
45 |
bulk |
Max size of transportation part MM |
6300x3100x3540mm |
7100x3400x3540mm |
8700x3800x3600mm |
14850x7800x10450mm |
Items/Model |
YSL-700-J |
YSL-1050-J |
YSL-2800-J |
Thermal output(Mkcal/MW) |
60Mkcal/0.7MW |
90Mkcal/1.05MW |
240Mkcal/2.8MW |
Rated presure Mpa |
0.7 |
0.7 |
1.0 |
Fuel consumption at full load operation kg/h |
180 |
270 |
720 |
Rated working temp. Deg C |
<300 |
<300 |
<300 |
Circulation oil volume m3 |
51 |
76 |
163 |
Total weight of equipment |
17.5 |
21.5 |
36 |
Overall size(LxWxH)mm |
2740x2350x3290mm |
3250x2360x3590mm |
6900x2720x3460mm |
Items/Model |
YSW-4200-J |
YSW-7000-J |
YSW-14000-J |
Thermal output(Mkcal/MW) |
360Mkcal/4.2MW |
600Mkcal/7.0MW |
1200Mkcal/14.0MW |
Rated presure Mpa |
1.0 |
1.0 |
1.0 |
Fuel consumption at full load operation kg/h |
1080 |
1800 |
3600 |
Heating area M2 |
271 |
350.3 |
735 |
Rated working temp. Deg C |
<300 |
<325 |
<325 |
Circulation oil volume m3 |
244 |
360 |
650 |
Total weight of equipment |
48 |
87.5 |
177.5 |
Overall size(LxWxH)mm |
8350x2900x3460mm |
9700x3300x6460mm |
17300x8550x11000mm |
Items/Model |
SHF4-1.25-J |
SHF6-1.25-J |
SHF10-1.25-J |
Rated output t/h |
4 |
6 |
10 |
Rated presure Mpa |
1.25 |
1.25 |
1.25 |
Steam temp. Deg C |
Saturated |
Saturated |
Saturated |
Feed water temp Deg C |
20 |
105 |
105 |
Combustion mode |
Fluidization suspension combustion |
Fluidization suspension combustion |
Fluidization suspension combustion |
Applicable fuel |
Coal water mixture |
Coal water mixture |
Coal water mixture |
Max elevation of boiler proper mm |
6000 |
6300 |
6700 |
Max size of transportation part MM |
8300x6800x6000mm |
8500x6800x6300mm |
10670x7550x6700mm |